Brand Name: | CSPPM |
Model Number: | PPM-TC1C21 |
MOQ: | 1 |
Packaging Details: | Standard package |
Paperless Recorder
Product introduction:
The PPM-TC1C21 series paperless recorder works with various sensors and transmitters to achieve the measurement, conversion, display, recording, dumping, communication and control of process quantities such as temperature, pressure, liquid level, and composition.
Features:
Graphic dot matrix LCD with 128x64 resolution, full Chinese interface, easy to operate
• The display content is rich and comprehensive, including measured values, engineering quantities, alarm information, real clock, real-time curve, historical curve, and recording status.
• Up to 4 channels of measurement input, suitable for voltage, current, thermal resistance, thermocouple, mV, remote pressure gauge and other types of signals.
• 4-point alarm output, 10 alarm modes can be selected, and alarm sensitivity can be set independently. With delayed alarm function,
Can remember the channel, time and alarm mode of the last 6 alarms.
• Fully transparent, high-speed, and efficient networked communication interface to achieve complete data transmission and control between the computer and the instrument.
• Unique control right transfer function enables the computer to directly control the alarm input and transmission output of the instrument.
• 4M memory for measurement value recording, can record 260,000 times of data. The data can be recalled through the historical curve and can be read through communication.
• With USB interface, the recorded historical data can be transferred to the U disk at any time.
• Good software platform with secondary development capabilities to meet special functional requirements.
• The product has obtained the electromagnetic compatibility (EMC) inspection certificate of the authority.
Product Selection Table :
Content | Code Description | ||||
TC1C21 |
1-4 Channel input; 0.2 level display accuracy; measurement and control speed (0.1 second x number of channels); |
||||
Dimension | 160x80x114.5mm cut out 152x75 | ||||
Panel Specification | 3 Inch gray text LCD on white(128x64) | ||||
Number of channels | 1~4 | 1 ~ 4 channel input; the standard configuration is 1 channel, on this basis, additional channels are added for additional costs. | |||
Input signal |
Universal input, select input signal through parameter setting Thermocouple(K/S/R/B/N/E/J/T);Thermal resistance(PtlOO/CulOO/Cu5O/G53/BAl/BA2 ); Voltage((0-5 )V/( 1-5 )V );Current((4-20 ) mA/ (0-20 )mA);millivolt(±100mV );Remote pressure gauge |
||||
Alarm (option)(250VAC/3A ,Resistive load) | T1-4 | 1 ~ 4 points relay output | |||
Transmitter(option) (Select up to 2 transmission outputs; resolution: 1/3000; load capacity: 600Ω) |
A1 | Current output(4 ~ 20)mA,(0 ~ 10)mA,(0 ~ 20)mA , 2 channels A1A1 | |||
A2 | Voltage output(1 ~ 5)V,(0 ~ 5)V , 2 channels A2A2 | ||||
A3 | Voltage output(0-10)V , 2 channel A3A3 | ||||
External power supply (optional, up to 2 external power supplies can be selected) | B1 | 24V±5% 50mA below | |||
BIG | 24V±5% 100mA below | ||||
B2 | 12V±5% 50mA below | ||||
B2G | 12V±5% 100mA OT | ||||
B3 | Precision power,Generally below 10V±2% , 30ppm.40mA | ||||
Communication (option) (Communication speed:2400,4800. 9600,19200) (Communication address:0~99) |
S1 | TC ASCII RS232 | |||
S2 | TC ASCH Protocol RS485 | ||||
Ml | Modbus-RTU Protocol RS232 | ||||
M2 | Modbus-RTU Protocol RS485 | ||||
USB dump interface (optional) | USB | When choosing this accessory, you must choose USB disk | |||
Power Specification | VO | 100-240VAC 50/60 Hz | |||
VI | 10-24V AC 50/60 Hz; 10-24V DC |
Brand Name: | CSPPM |
Model Number: | PPM-TC1C21 |
MOQ: | 1 |
Packaging Details: | Standard package |
Paperless Recorder
Product introduction:
The PPM-TC1C21 series paperless recorder works with various sensors and transmitters to achieve the measurement, conversion, display, recording, dumping, communication and control of process quantities such as temperature, pressure, liquid level, and composition.
Features:
Graphic dot matrix LCD with 128x64 resolution, full Chinese interface, easy to operate
• The display content is rich and comprehensive, including measured values, engineering quantities, alarm information, real clock, real-time curve, historical curve, and recording status.
• Up to 4 channels of measurement input, suitable for voltage, current, thermal resistance, thermocouple, mV, remote pressure gauge and other types of signals.
• 4-point alarm output, 10 alarm modes can be selected, and alarm sensitivity can be set independently. With delayed alarm function,
Can remember the channel, time and alarm mode of the last 6 alarms.
• Fully transparent, high-speed, and efficient networked communication interface to achieve complete data transmission and control between the computer and the instrument.
• Unique control right transfer function enables the computer to directly control the alarm input and transmission output of the instrument.
• 4M memory for measurement value recording, can record 260,000 times of data. The data can be recalled through the historical curve and can be read through communication.
• With USB interface, the recorded historical data can be transferred to the U disk at any time.
• Good software platform with secondary development capabilities to meet special functional requirements.
• The product has obtained the electromagnetic compatibility (EMC) inspection certificate of the authority.
Product Selection Table :
Content | Code Description | ||||
TC1C21 |
1-4 Channel input; 0.2 level display accuracy; measurement and control speed (0.1 second x number of channels); |
||||
Dimension | 160x80x114.5mm cut out 152x75 | ||||
Panel Specification | 3 Inch gray text LCD on white(128x64) | ||||
Number of channels | 1~4 | 1 ~ 4 channel input; the standard configuration is 1 channel, on this basis, additional channels are added for additional costs. | |||
Input signal |
Universal input, select input signal through parameter setting Thermocouple(K/S/R/B/N/E/J/T);Thermal resistance(PtlOO/CulOO/Cu5O/G53/BAl/BA2 ); Voltage((0-5 )V/( 1-5 )V );Current((4-20 ) mA/ (0-20 )mA);millivolt(±100mV );Remote pressure gauge |
||||
Alarm (option)(250VAC/3A ,Resistive load) | T1-4 | 1 ~ 4 points relay output | |||
Transmitter(option) (Select up to 2 transmission outputs; resolution: 1/3000; load capacity: 600Ω) |
A1 | Current output(4 ~ 20)mA,(0 ~ 10)mA,(0 ~ 20)mA , 2 channels A1A1 | |||
A2 | Voltage output(1 ~ 5)V,(0 ~ 5)V , 2 channels A2A2 | ||||
A3 | Voltage output(0-10)V , 2 channel A3A3 | ||||
External power supply (optional, up to 2 external power supplies can be selected) | B1 | 24V±5% 50mA below | |||
BIG | 24V±5% 100mA below | ||||
B2 | 12V±5% 50mA below | ||||
B2G | 12V±5% 100mA OT | ||||
B3 | Precision power,Generally below 10V±2% , 30ppm.40mA | ||||
Communication (option) (Communication speed:2400,4800. 9600,19200) (Communication address:0~99) |
S1 | TC ASCII RS232 | |||
S2 | TC ASCH Protocol RS485 | ||||
Ml | Modbus-RTU Protocol RS232 | ||||
M2 | Modbus-RTU Protocol RS485 | ||||
USB dump interface (optional) | USB | When choosing this accessory, you must choose USB disk | |||
Power Specification | VO | 100-240VAC 50/60 Hz | |||
VI | 10-24V AC 50/60 Hz; 10-24V DC |